Enhanced TDS
Identification & Functionality
- Chemical Family
- RTU Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- General Information about MMA adhesives
2-component methacrylate adhesives belong to the group of reactive adhesives. The reaction starts by mixing hardener and resin. Cyberbond offers these adhesives in double cartridges in 1:1 or 10:1 ratio with static mixing tubes. This allows an easy and quick application. Methacrylate adhesives are available in different viscosities from liquid to paste-like and with different curing times. They are characterized by excellent adhesion to metals, many plastics and composite materials. The mechanical properties range from flexible to rigid.
Applications & Uses
- Markets
- Applications
- Compatible Substrates & Surfaces
- Clean Surface
Surfaces should be clean, dry and free of grease before bonding.
Properties
- Physical Properties
Value Units Test Method / Conditions Cure Time (Full, Polymer) 24 h - Density (A/B, Liquid state) 1.07 g/cm³ - Mix Ratio (Liquid state) 10:1 - - Open Time (Liquid State) 2 - 3 minutes - Fixture Time (Liquid State) 10 - 15 minutes - Temperature Range (Polymer) -40 - 120 °C - Viscosity (Cone/plate, at 20°C, 0.5 s-1) 200.000 - 400.000 mPa.s - - Typical Properties
Value Units Test Method / Conditions E-modulus 150 - 300 MPa - Elongation at Break 180 - 200 % - Set Time 10 - 15 min - Storage Temperature 10 - 20 °C - Tensile Strength 9 - 12 MPa -
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Technical Information
Adhesive performance Tensile Shear Strength Substrate N/mm² Tensile shear strength (Polypropylene PP, Substrate Failure) 2,5 - 4 Tensile shear strength (Polyethylene PE, Substrate Failure) 2,5 - 4 Tensile shear strength (PP to Stainless Steel, Substrate Failure) 5 - 6 Tensile shear strength (PE to Stainless Steel, Substrate Failure) 3 - 4 Tensile shear strength (PP to Aluminum, Substrate Failure) 5 - 6 Tensile shear strength (PE to Aluminum, Substrate Failure) 3 - 4 Tensile Shear Strength

Resistance Against Solvents
Solvent Resistance Weak acids very good Weak bases very good Polar solvents limited Strong acids and bases limited Measurement of Viscosity
Viscosity describes the flow-ability of a liquid. Cyberbond measures the viscosity of the products by means of the cone/plate method: the liquid is applied on a panel and a defined cone presses the liquid together and rotates. Newtonian fluids are measured at shear rate 160 s-1, thixotropic products are measured at shear rate 0,5 s-1 and 160 s-1. The viscosity is measured in mPa*s at 20 °C.
Safety & Health
- Safety Information
- Keep the workplace clean and use in well ventilated areas only. Installll suitable exhaust system at the workplace.
- Wear suitable safety glasses and gloves.
- Keep away from heat, hot surfaces, sparks, open flames and other ignition sources.
Packaging & Availability
- Packaging Type
- Regional Availability
Storage & Handling
- Shelf Life
- 9 Months
- Storage Conditions
Store products in a cold and dark place at temperatures between 10 °C to 20 °C.