Advantra® PHC-9254 is a superior, wide-range-grade case and carton hot melt adhesive with great performance at both low and high temperatures. An outstanding troubleshooting grade It ensures superior bonding, thermal stability, clean machining, and a low total cost of ownership. Even at extremely low temperatures, this hot melt adhesive offers the sealing advantage your business needs.

Product Type: Hot Melt Adhesive, Reactive Adhesive

Application Area: Blast Freezer, Bliss Box, Cartons, Case Sealing, Cases, Trays

Compatible Substrates & Surfaces: Clay-coated News Back, Styrene Butadiene Styrene (SBS)

Features: Excellent Performance, Fast Setting, Good Adhesion, High Temperature Performance, Hot Tack Strength, Long Open Time, Low Density, Low Odor, Low Temperature Performance

Message our experts with questions
Robert Blackstone avatar

Robert Blackstone

Global Leader - Inside Sales

Please reach out to me with any questions, I am happy to assist you in finding the right product or learning more about our storefront

Enhanced TDS

Identification & Functionality

Features & Benefits

Applications & Uses

Markets
Applications
Application Area
Compatible Substrates & Surfaces
Typical Applications
  • Hot Fill to Blast Freezer
  • Cases
  • Cartons
  • Trays
  • Bliss Box
  • Hot and cold environments
  • High springback containers.
Suitable Substrates

Uncoated to moderately coated Corrugated, Clay Coated, SBS, SUS and similar materials.

Cleaning Instructions

Consult the equipment manufacturer for cleanup procedures. After clean-up, flush the applicator thoroughly with hot melt to purge the system.

Properties

Color
Physical Form
Typical Properties
ValueUnitsTest Method / Conditions
Suggested Application Temperature350.0°F-
Viscosity (at 325°F)1.655cPs-
Viscosity (at 350°F)1.015 - 1.285cPs-
Viscosity (at 375°F)785.0cPs-
Color (Molten)1 - 2-Gardner
Softening Point (Mettler)215 - 235°F-
Specific Gravity0.97--
Speed of Set (Relative)Very Fast--

Regulatory & Compliance

Technical Details & Test Data

Viscosity Curve

Advantra® PHC-9254 - Viscosity Curve

Safety & Health

Safety Information

To minimize the risk of burns, we recommend the use of eye protection and protective clothing when working near a hot melt applicator. To minimize the risk of flammable vapors, do not exceed a melt temperature above 400°F. Prevent the build-up of vapors. Extinguish all sources of ignition during hot melt use.

Packaging & Availability

Regional Availability
  • North America

Storage & Handling

Shelf Life
730 Days
Storage Conditions

Clean and dry conditions above 20°F and below 100°F.