Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
Applications & Uses
- Application Area
- Application Method
- Drying Time
- 30-60 must be thoroughly dry before process equipment can be used at design operating temperatures.
- Total drying time is approximately 48 hours depending on ambient conditions.
- Dry time can be accelerated by air drying 4 hours, followed by heating up Foster 30-60 for 24 hours (to maintain 30-60 at 82°C to 93°C).
- Cleaning Information
Use clean fresh water to clean tools and equipment before 30-60 dries
Properties
- Typical Properties
- Application Properties
Value | Units | Test Method / Conditions | |
Average Density | 1.67 | kg/l | - |
Average Non-Volatile (by Weight) | 71.5 | % | - |
Coverage Range (for 9.5 mm Outside Diameter Tracer) | approx. 0.25 | ltr/m | - |
Coverage Range (for 12.7 mm Outside Diameter Tracer) | approx. 0.35 | ltr/m | - |
Coverage Range (for 19.0 mm Outside Diameter Tracer) | approx. 0.75 | ltr/m | - |
Coverage Range (for 25.4 mm Outside Diameter Tracer) | approx. 1.00 | ltr/m | - |
Drying Time (Set to Touch) | 2.0 | Hours | - |
Thermal Conductivity | 15.0 | W/mK | - |
Compressive Strength | 1300.0 | psi | ASTM D695 |
Tensile Strength | 255.0 | psi | ASTM D638 |
Linear Shrinkage (on Metal Surfaces) | 1.0 | % | - |
Value | Units | Test Method / Conditions | |
Service Temperature Range (Continuous) | -73 to 315 | °C | - |
Service Temperature Range (Intermittent) | -73 to 400 | °C | - |
Storage & Handling
- Shelf Life
- 6 months
- Handling Conditions
- Store between 40°F (4°C) and 90°F (32°C).
- Apply between 40°F (4°C) and 100°F (38°C).
- Do not apply over aluminum.
- Use within six months for best application properties.
- Protect 30-60 from rain until insulation is installed.
- To ensure good bond to bare metal, surface must be clean, dry and free of rust, scale, oil or mill scale prior to attaching the tracer and applying 30-60.
- A portable sandblaster or a grinding wheel can be used for cleaning metal surface.
- Apply 30-60 by glove, pointed trowel, or pressure extrusion equipment, being careful to force 30-60 into the crevice between tracer and pipeline.
- 30-60 should cover the tracer by at least 6 mm.
- The contact area of 30-60 on the pipe or vessel should be three times the width of the tracer.