Foster® Vapor-Safe® Coating AF 30-80AF™
1 of 73 products in this brandRTU Product Type: Coating, Waterborne Coating, Waterborne Sealant
Application Area: All Service Jackets (ASJ), Board Facings, FRK Jackets, FSK Jackets, Lap Sealing, Over Staple , Weld Pin Punctures
Application Method: Air Less Spray, Brush
Compatible Substrates & Surfaces: Concrete, Polystyrene (PS) Foam
Features: Fire-Resistant, Flexible, Low Water Permeability, UV Resistant, Water-based, Water Resistant
Enhanced TDS
Identification
- GBU
- RTU Product Type
- Categories
Applications
- Application Area
- Application Method
- Compatible Substrates & Surfaces
Applications & Uses
- Cleaning Information
-
- Use fresh water for cleaning brushes and equipment before product dries.
- Dry product may be removed with hot soapy water (with ammonia added) or strong solvents such as chlorinated solvent (non-flammable) or xylol (flammable).
- Preparation and Application Information
-
Preparation
- Stir well, Do not thin.
- Apply only to clean, dry, oil-free surfaces.
- Keep container closed when not in use.
Application
- To prevent water vapor and moisture infiltration, proper and complete flashing is required.
- Follow flashing specifications.
Indoor and light duty outdoor
- Apply tack coat of Foster® VAPOR-SAFE® Coating AF at 2 – 4 gallons per 100 square feet (0.8 – 1.6 l/m2 ).
- Embed Foster® MAST-A-FAB® White Membrane into the wet tack coat. Smooth membrane to avoid wrinkles and overlap all seams at least two inches (5 cm). Apply finish coat of VAPOR-SAFE® Coating AF, within 1/2 hour of the tack coat application, at 2 gallons per 100 square feet (0.8 l/m2 ).
- This application shall provide a minimum dry film thickness of 37 – 56 mils (0.9 – 1.4 mm).
- Do not use with canvas or other closed weave cloths.
Brush
- Use a good brush (suitable for water-based paints), making strokes as long as possible over the surface.
- Apply with full brush and spread out evenly.
- Do not overwork.
Spray
- VAPOR-SAFE® Coating AF may be airless spray applied.
- For spray equipment information, please consult Airless Spray Recommendations or contact your airless spray equipment supplier.
- Average viscosity range: 60,000 – 90,000 cps.
- Corrosion resistant pumps and fittings are suggested.
Features
- Ready-to-Use Product Features
Features & Benefits
- Labeling Claims
- Product Highlights
-
- FOSTER® VAPOR-SAFE® COATING AF is a water-based, fire- resistive, flexible, high solids, vapor retarder finish for most types of thermal insulation, including polystyrene foam.
- It may be used over dry concrete and finishing cement.
- It is designed for use in high humidity areas to resist mold, fungus and mildew growth on its surface and protect the insulation system from their discoloring and deteriorating effects.
- VAPOR-SAFE® 30-80AF™ has the water resistance and low water vapor permeance normally only found in solvent-based products.
- It can be used in high humidity environments and greatly retards water vapor permeation.
- It is non-flammable in the wet state.
- VAPOR-SAFE® 30-80AF™ is formulated for both indoor and light duty, commercial, outdoor use.
- It is UV resistant. It has a mild, latex “paint- type” odor, and is designed for use over insulation on pipes, vessels, ducts and equipment operating below ambient temperatures.
- VAPOR-SAFE® 30-80AF™ is ideal for vapor sealing ASJ, FRK and FSK jackets and board facings at joints, laps and over staple and weld pin punctures.
- It is an excellent duct board closure sealant. Do not exceed 1/8” (3.2 mm) wet film thickness.
- VAPOR-SAFE® 30-80AF™ meets the requirements of Military Specification MIL-PRF-19565C, Type II using method AS™ E96, Procedure A permeance.
- VAPOR-SAFE® COATING 30-80AF™ meets the requirements of:
- MAS Certified Green®
- California Dept. of Public Health Standard Method v1.2
- VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings
- Collaborative for High Performance Schools EQ 7.1
Packaging & Availability
- Regional Availability
Physical Properties
- Color (Properties)
- Physical Form
Properties
- Shelf Life:
-
12 months
- Application Properties
-
Value Units Test Method / Conditions Application Temperature 4 - 38 °C - Average Viscosity 60000 - 90000 cPs - Service Temperature Limits (tested at coverage rate of 0.61 m²/l in a 4” strip, applied to 6.4 mm inorganic reinforced cement board) -29 to 82 °C - - Typical Properties
-
Value Units Test Method / Conditions Coverage Range 4 - 6 gal./100 sq. ft - Density 11.5 lbs/gal ASTM D1475 Drying Time (at 23°C, 50% RH, set to touch) 4 hours - Drying Time (at 23°C, 50% RH, through dry) 24 hours - Flash Point (wet flammability) 100 °C - Fungal Growth Resistance 0 rating ASTM D5590 Non-Volatile Content (average) 58 Vol(%) ASTM D2369 Non-Volatile Content (average) 70 Wt(%) ASTM D2369 Storage Temperature 4 - 38 °C - Volatile Organic Compound Content 36 g/L - Water Vapor Permeance (at 1.2 mm, dry film thickness) 0.03 perms ASTM E96, Procedure A Water Vapor Permeance (at 1.2 mm, dry film thickness) 0.05 perms ASTM E96, Procedure A Water Vapor Permeance (at 38°C, 90% RH, 0.94 mm dry film thickness) 0.08 perms ASTM F1249 - Flame Characteristics
-
Value Units Test Method / Conditions Smoke Developed 30 - ASTM E84 Surface Flame Spread (tested at coverage rate of 0.61 m²/l in a 4” strip, applied to 6.4 mm inorganic reinforced cement board) 15 - ASTM E84
Regulatory & Compliance
- Certifications & Compliance
- Chemical Inventories
- Quality Standards
Storage & Handling
- Handling Conditions
-
- Store and apply between 40°F (4°C) and 100°F (38°C), protect from freezing until dry.
- To resist rain wash-off, allow at least 8-12 hours drying time above 50°F (10°C), with a relative humidity of 50%.
- Higher humidity and/or lower temperature may retard drying.
- Always select coating in the white color for use over polystyrene on outdoor installations.
- After long term exposure, 30-80AF™ may weather to an off-white color.
- Always test foil and paper facings for acceptable adhesion before using.
- Outdoor horizontal surfaces must always drain completely.
- A pitch of at least 1/2” per foot (4 cm/m) is required.
- This product does not protect users or others against bacteria, viruses, germs or other disease organisms.
- It does not take the place of normal cleaning and disinfecting procedures.
- Shelf Life
-
12 months