Enter your search in the bar above and start exploring our products.

Foster® Cryogenic Adhesive 82-77

1 of 39 products in this brand
Foster® Cryogenic Adhesive 82-77 is a chemically curing adhesive with the capability to achieve high tensile strength and adhesion at room temperature. It effectively bonds to a range of surfaces, including metal, wood, and masonry. This adhesive is supplied in a virtually 100% solids form, facilitating immediate bonding for non-porous surfaces without the risk of solvent entrapment issues.

Chemical Family: Epoxy & Epoxy Derivatives

RTU Product Type: Adhesive

Labeling Claims: Hazardous Air Pollutants (HAPs)-free

Application Area: Cryogenic Applications

Application Method: Trowel

View All Documents

Enhanced TDS

Identification

Chemical Family
GBU
RTU Product Type
Blend
true
Single Ingredient
false

Categories

Applications

Application Area
Application Method
Compatible Polymers & Resins
Compatible Substrates & Surfaces

Applications & Uses

Preparation and Application Information

Material Preparation

  • Mixing Instructions: Mix Part A and B in a clean container with a cage type mixing paddle and a 1/2 inch (12.7 mm) heavy duty electric drill on slow speed (350 rpm).
  • Mix thoroughly for 3 minutes, making sure to scrape the sides and the bottom of the container. While mixing, slowly add Part C (aggregate) and mix an additional 2 to 3 minutes until uniform.
  • Do not lengthen or shorten the mixing time.
  • Do Not Thin.
  • Mixing Ratios: Foster® Cryogenic Adhesive is supplied in 40 lb. kits.
  • Either mix the entire kit or divide each component into 2 equal parts and mix half of the kit at one time.
  • Do not attempt to mix less than half of a kit.

Application

  • Apply by trowel to clean, dry surfaces only.
  • Metal surfaces should be solvent cleaned beforehand and allowed to dry.
  • When used in cryogenic applications (below -40°F/-4°C), for maximum adhesion the metal surface must be clean and free of any surface contaminants and sandblasted, sanded/roughened or primed with a polyamide epoxy primer.

Application Temperature 

  • Apply between 60°F and 100°F ambient temperature.
  • At temperatures above 95°F, the pot life will be less than 30 minutes.
  • To prolong pot life at high temperatures, Foster® Crogenic Adhesive should be spread out as much as possible immediately after mixing.

Coverage Range 

  • When used as a bedding compound or between surfaces of masonry or urethane foam, suggested thickness: 1/16 to 1/4 inch (1.6 to 6.4 mm).
  • When used in cryogenic applications or where bonding to metal, suggested thickness: 1/16 to 1/8 inch (1.6 to 3.2 mm).

Clean Up 

  • Before adhesive cures, clean tools and equipment with chlorinated solvent (non-flammable) or mineral spirits (flammable). Cured 82- 77 is extremely difficult to remove.

End Uses

Adhesive & Sealant End Applications

Features

Ready-to-Use Product Features

Features & Benefits

Labeling Claims
Product Highlights
  • Cryogenic adhesive also can be used as a fabricating adhesive.
  • It often provides bonds stronger than the materials being joined.
  • The cured film has excellent resistance to solvents, water, and many chemicals.
  • The adhesive also performs well with various materials after thermal shock exposure at cryogenic temperatures.
  • It is an ideal choice for bonding steel pipe shoes or saddles to pipe insulation assemblies.
  • Cryogenic adhesive meets requirements for LEED IEQ 4.1 Low-Emitting Materials, Adhesives, and Sealants.

Packaging & Availability

Regional Availability
  • Asia Pacific
  • Europe
  • North America
  • Latin America
  • India/MiddleEast/Africa (IMEA)

Physical Properties

Color (Properties)
Physical Form

Properties

Pot Life:
0.5 hours
Shelf Life:
12 months
Note

¹ - Supplied as a 3-part 40 lb. kit. 15.5 lbs./gal. yields 2.6 gallons

² - At very low cryogenic temperatures (past -100°C), cellular glass to other metals, such as aluminum, may result in shear failure of the insulation due to differences in contraction  rates of the metal and insulation.

Application Properties
Value Units Test Method / Conditions
Application Temperature 16 - 38 °C -
Service Temperature Limits (at coated surface) -196 to 121 °C -
Service Temperature Limits (cellular glass insulation to stainless steel) -196 to 121 °C -
Service Temperature Limits (cellular glass to cellular glass insulation) -196 to 121 °C -
Typical Properties
Value Units Test Method / Conditions
Blended Average Weight¹ 15.5 lbs/gal ASTM D1475
Bonding Time Range (Open Time) 0 - 2 hours -
Bonding Time Range (cure through) 12 - 24 hours -
Bonding Time Range (full cure) 1 week -
Bonding Time Range (set) 4 hours -
Coverage (at 1/16 inch) 66.7 ft² -
Coverage (at 1/4 inch) 16.7 ft² -
Coverage (at 1/8 inch) 33.4 ft² -
Flash Point (wet flammability) 121 °C -
Pot Life (at 23°C) 1.5 hours -
Pot Life (at 35°C) 0.5 hour -
Storage Temperature 4 - 38 °C -

Regulatory & Compliance

Certifications & Compliance
Chemical Inventories

Storage & Handling

Handling Conditions
  • Store between 40°F (4°C) and 100°F (38°C).
  • Apply between 60°F (16°C) and 100°F (38°C).
  • Pot life is longer at lower temperatures and shorter at higher temperatures.
  • Mixing large quantities also shortens pot life, thus mixing more than one kit at a time is not recommended.