Enhanced TDS
Identification & Functionality
- Equipment Type
- Technologies
- Product Families
Features & Benefits
- Equipment Features
- Product Features
- Lightweight and portable
- Clean, contained delivery system
- Quick and easy application
- Solid core tires
- Adjustable gun assembly
- Dual pump system
- Single aperture
- Product Benefits
- Easy to maneuver
- Applicator and hoses stay clean and free flowing, low maintenance
- Perfect for large congested rooftops
- Prevents flat tires
- Ergonomic design
- Reduces risk of catastrophic pump failure and lowers maintenance cost
- Easy connections
Applications & Uses
- Markets
- Applications
- Application Area
- Shut Down and Extended Breaks
- Close manifold valves.
- Turn off power.
- Remove static mixing tip and retaining nut (if needed) and discard.
- Relieve any pressure in hoses by opening and closing applicator valves.
- Pump a non-lithium grease into both grease fittings on the gun manifold until it flows out of the tip. Install grease into the Part 1 (A) grease fitting first.
- Caution: Remove static mixing nozzle during any pause in application or operation. Do not allow pressure to build up in the static mixing nozzle. If static mixing nozzle remains on applicator manifold, material can react and harden in the manifold and possibly the ends of the hoses. During removal and attachment of static mixing nozzles, a wrench may be necessary for removal. Clean manifold threads and re-grease frequently.
- Product Limitation
- Do not apply to wet or damp surfaces.
- Not recommended for use with insulation boards larger than 4’ x 4’ (1.2m x 1.2m).
- Do not use warped or curled insulation boards. All insulation boards must lay flat upon the roof surface.
- Pump grade adhesives are designed for application temperatures of 40°F and above.
- Surface Preparation
-
All work surfaces should be clean, dry, and free of dirt, dust, debris, oils, loose and/or embedded gravel, un-adhered coatings, deteriorated membrane and other contaminants that may result in a surface that is not sound or is uneven. In recover applications Millennium Surface Treatment or Millennium Universal Primer may be required.
-
Properties
- Soluble In
- Coverage Rate
Ribbon Application
- 5 Gallon (18.9L) Kit: 2,500-3,000 sq. ft. (232m²-279m²)
- 15 Gallon (56.7L) Kit: 7,500-9,000 sq. ft. (697m²-836m²)
Controlled Low-Pressure Spray Application
- 5 Gallon (18.9L) Kit: 1,300-1,800 sq. ft. (121m²-167m²)
- 15 Gallon (56.7L) Kit: 3,900-5,400 sq. ft. (362m²-502m²)
Coverage estimates indicate total square feet of insulation/membrane attachment per kit. Rates are based on an application pattern of four 1/2” - 3/4” (1.3cm - 1.9cm) beads spaced 12” (30cm) o.c. per 4’ x 4’ (1.2m x 1.2m) insulation board.
Note: A 1/2” - 3/4” (1.3cm - 1.9cm) wide uncured adhesive bead will produce a 2” - 3” (5.1cm - 7.6cm) wide cured adhesive bead that will rise approximately 3/4” - 1” (1.9cm - 2.5cm) above the substrate. Coverage rates may be lower when used over irregular surfaces and will vary depending on roughness.
- Coverage Rate
Ribbon Application
- 5 Gallon (18.9L) Kit: 2,500-3,000 sq. ft. (232m²-279m²)
- 15 Gallon (56.7L) Kit: 7,500-9,000 sq. ft. (697m²-836m²)
Controlled Low-Pressure Spray Application
- 5 Gallon (18.9L) Kit: 1,300-1,800 sq. ft. (121m²-167m²)
- 15 Gallon (56.7L) Kit: 3,900-5,400 sq. ft. (362m²-502m²)
Coverage estimates indicate total square feet of insulation/membrane attachment per kit. Rates are based on an application pattern of four 1/2” - 3/4” (1.3cm - 1.9cm) beads spaced 12” (30cm) o.c. per 4’ x 4’ (1.2m x 1.2m) insulation board.
Note: A 1/2” - 3/4” (1.3cm - 1.9cm) wide uncured adhesive bead will produce a 2” - 3” (5.1cm - 7.6cm) wide cured adhesive bead that will rise approximately 3/4” - 1” (1.9cm - 2.5cm) above the substrate. Coverage rates may be lower when used over irregular surfaces and will vary depending on roughness.
Packaging & Availability
- Regional Availability
- Packaging Information
Millennium PG-1 Fleeceback Membrane Adhesive and Low Viscosity Insulation Adhesive Kit:
- Part 1 (A): 5 gallon (18.9L) Box – PG-IA5B-A01
- Part 2 (B): 5 gallon (18.9L) Box – PG-IA5B-B01
- Packaging Information
Millennium PG-1 Fleeceback Membrane Adhesive and Low Viscosity Insulation Adhesive Kit:
- Part 1 (A): 5 gallon (18.9L) Box – PG-IA5B-A01
- Part 2 (B): 5 gallon (18.9L) Box – PG-IA5B-B01
Storage & Handling
- Safety Information
- Protective equipment such as safety glasses and protective gloves must be worn when operating or servicing the Millennium Cyclone pump cart.
- The Patented Millennium Cyclone pump cart runs on 110-volt 60Hz AC current.
- Use a grounded power cord that is in good condition, rated for outdoor use, and a minimum of 14-gauge construction.
- Servicing electrical components should only be done by trained personnel and only after disconnecting power to the equipment.
- Caution: The electrical circuitry is not explosion-proof and should not be used in any environment requiring such a design.
- The Patented Millennium Cyclone pump cart operates with pressure.The applicator should never be pointed toward people.
- The applicator should never be actuated when the outlet tip is blocked or restricted by cured adhesive or any object.
- Machine Storage Conditions
- Long-term storage (30 days or more) will require that the pump system and hoses are flushed with Millennium Cyclone System Solution.
- After extended storage, the gravity feed supply lines and quick connects may need to be replaced.
- Material can be allowed to stand in the machine for short periods of time; however, it is very important that Part 1 not be exposed to air or moisture to prevent crystallization.
- Material should be run through the pump and hoses every three to four weeks when the pump is not in use.
- Cyclone System Solution can be run through the pump for this purpose
- Machine Storage Conditions
- Long-term storage (30 days or more) will require that the pump system and hoses are flushed with Millennium Cyclone System Solution.
- After extended storage, the gravity feed supply lines and quick connects may need to be replaced.
- Material can be allowed to stand in the machine for short periods of time; however, it is very important that Part 1 not be exposed to air or moisture to prevent crystallization.
- Material should be run through the pump and hoses every three to four weeks when the pump is not in use.
- Cyclone System Solution can be run through the pump for this purpose