Millennium Cyclone 5/15 VS Plus Pump Cart

1 of 55 products in this brand
Millennium Cyclone 5/15 VS Plus Pump Cart is an application equipment designed with a dual-speed feature for low-pressure spray or ribbon application. It enables fast and cost-effective installation of fleeceback membranes. The pump cart also includes an easy tilt-up drum loading feature. It is specifically used for dispensing two-component 1:1 ratio low-rise foam polyurethane adhesives, whether through low-pressure spray or traditional bead application.
Technical Data Sheet
  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Features & Benefits

Equipment Features
Product Features
  • Lightweight and portable
  • Clean, contained delivery system
  • Quick and easy application
  • Solid core tires
  • Adjustable gun assembly
  • Dual pump system
  • Single aperture
Product Benefits
  • Easy to maneuver
  • Applicator and hoses stay clean and free flowing, low maintenance
  • Perfect for large congested rooftops
  • Prevents flat tires
  • Ergonomic design
  • Reduces risk of catastrophic pump failure and lowers maintenance cost
  • Easy connections

Applications & Uses

Markets
Applications
Application Area
Shut Down and Extended Breaks
  • Close manifold valves.
  • Turn off power.
  • Remove static mixing tip and retaining nut (if needed) and discard.
  • Relieve any pressure in hoses by opening and closing applicator valves.
  • Pump a non-lithium grease into both grease fittings on the gun manifold until it flows out of the tip. Install grease into the Part 1 (A) grease fitting first.
  • Caution: Remove static mixing nozzle during any pause in application or operation. Do not allow pressure to build up in the static mixing nozzle. If static mixing nozzle remains on applicator manifold, material can react and harden in the manifold and possibly the ends of the hoses. During removal and attachment of static mixing nozzles, a wrench may be necessary for removal. Clean manifold threads and re-grease frequently.
Product Limitation
  • Do not apply to wet or damp surfaces.
  • Not recommended for use with insulation boards larger than 4’ x 4’ (1.2m x 1.2m).
  • Do not use warped or curled insulation boards. All insulation boards must lay flat upon the roof surface.
  • Pump grade adhesives are designed for application temperatures of 40°F and above.
Surface Preparation
  • All work surfaces should be clean, dry, and free of dirt, dust, debris, oils, loose and/or embedded gravel, un-adhered coatings, deteriorated membrane and other contaminants that may result in a surface that is not sound or is uneven. In recover applications Millennium Surface Treatment or Millennium Universal Primer may be required.

Properties

Soluble In
Coverage Rate

Ribbon Application

  • 5 Gallon (18.9L) Kit: 2,500-3,000 sq. ft. (232m²-279m²)
  • 15 Gallon (56.7L) Kit: 7,500-9,000 sq. ft. (697m²-836m²)

Controlled Low-Pressure Spray Application

  • 5 Gallon (18.9L) Kit: 1,300-1,800 sq. ft. (121m²-167m²)
  • 15 Gallon (56.7L) Kit: 3,900-5,400 sq. ft. (362m²-502m²)

Coverage estimates indicate total square feet of insulation/membrane attachment per kit. Rates are based on an application pattern of four 1/2” - 3/4” (1.3cm - 1.9cm) beads spaced 12” (30cm) o.c. per 4’ x 4’ (1.2m x 1.2m) insulation board.

Note: A 1/2” - 3/4” (1.3cm - 1.9cm) wide uncured adhesive bead will produce a 2” - 3” (5.1cm - 7.6cm) wide cured adhesive bead that will rise approximately 3/4” - 1” (1.9cm - 2.5cm) above the substrate. Coverage rates may be lower when used over irregular surfaces and will vary depending on roughness.

Coverage Rate

Ribbon Application

  • 5 Gallon (18.9L) Kit: 2,500-3,000 sq. ft. (232m²-279m²)
  • 15 Gallon (56.7L) Kit: 7,500-9,000 sq. ft. (697m²-836m²)

Controlled Low-Pressure Spray Application

  • 5 Gallon (18.9L) Kit: 1,300-1,800 sq. ft. (121m²-167m²)
  • 15 Gallon (56.7L) Kit: 3,900-5,400 sq. ft. (362m²-502m²)

Coverage estimates indicate total square feet of insulation/membrane attachment per kit. Rates are based on an application pattern of four 1/2” - 3/4” (1.3cm - 1.9cm) beads spaced 12” (30cm) o.c. per 4’ x 4’ (1.2m x 1.2m) insulation board.

Note: A 1/2” - 3/4” (1.3cm - 1.9cm) wide uncured adhesive bead will produce a 2” - 3” (5.1cm - 7.6cm) wide cured adhesive bead that will rise approximately 3/4” - 1” (1.9cm - 2.5cm) above the substrate. Coverage rates may be lower when used over irregular surfaces and will vary depending on roughness.

Packaging & Availability

Regional Availability
  • Asia Pacific
  • Latin America
  • North America
Packaging Information

Millennium PG-1 Fleeceback Membrane Adhesive and Low Viscosity Insulation Adhesive Kit:

  • Part 1 (A): 5 gallon (18.9L) Box – PG-IA5B-A01
  • Part 2 (B): 5 gallon (18.9L) Box – PG-IA5B-B01
Packaging Information

Millennium PG-1 Fleeceback Membrane Adhesive and Low Viscosity Insulation Adhesive Kit:

  • Part 1 (A): 5 gallon (18.9L) Box – PG-IA5B-A01
  • Part 2 (B): 5 gallon (18.9L) Box – PG-IA5B-B01

Storage & Handling

Safety Information
  • Protective equipment such as safety glasses and protective gloves must be worn when operating or servicing the Millennium Cyclone pump cart.
  • The Patented Millennium Cyclone pump cart runs on 110-volt 60Hz AC current.
  • Use a grounded power cord that is in good condition, rated for outdoor use, and a minimum of 14-gauge construction.
  • Servicing electrical components should only be done by trained personnel and only after disconnecting power to the equipment.
  • Caution: The electrical circuitry is not explosion-proof and should not be used in any environment requiring such a design.
  • The Patented Millennium Cyclone pump cart operates with pressure.The applicator should never be pointed toward people.
  • The applicator should never be actuated when the outlet tip is blocked or restricted by cured adhesive or any object.
Machine Storage Conditions
  • Long-term storage (30 days or more) will require that the pump system and hoses are flushed with Millennium Cyclone System Solution.
  • After extended storage, the gravity feed supply lines and quick connects may need to be replaced.
  • Material can be allowed to stand in the machine for short periods of time; however, it is very important that Part 1 not be exposed to air or moisture to prevent crystallization.
  • Material should be run through the pump and hoses every three to four weeks when the pump is not in use.
  • Cyclone System Solution can be run through the pump for this purpose
Machine Storage Conditions
  • Long-term storage (30 days or more) will require that the pump system and hoses are flushed with Millennium Cyclone System Solution.
  • After extended storage, the gravity feed supply lines and quick connects may need to be replaced.
  • Material can be allowed to stand in the machine for short periods of time; however, it is very important that Part 1 not be exposed to air or moisture to prevent crystallization.
  • Material should be run through the pump and hoses every three to four weeks when the pump is not in use.
  • Cyclone System Solution can be run through the pump for this purpose