Enter your search in the bar above and start exploring our products.

H.B. Fuller EV Bond 720

1 of 48 products in this brand
H.B. Fuller EV Bond 720 is designed to set quickly and strengthen within 3-4 minutes. Fully moisture-cured material displays excellent high temperature strength, tested up to 120°C. Rapid shipment of bonded parts is possible, as H.B. Fuller EV Bond 720 will not flow or expulse at 120°C, preserving bonded geometry at high temperatures before fully moisture-cured. This patented reactive hot melt moisture curing material is a one component polyurethane, 100% solid adhesive. Excellent adhesion strength is achieved within 10 seconds to 3 minutes after dispensing. This product has aggressive hot tack and cures in the presence of moisture into a tough bond. It works well in bonding various plastics, woods, metals, and primed glass substrates.

RTU Product Type: 1K (1 component) Adhesive, Hot Melt Reactive Adhesive, Solvent free (100% Solids) Adhesive

Application Area: Batteries, Electric Vehicle (EV)

Compatible Substrates & Surfaces: Glass, Glass, Primed, Metal, Plastics, Wood

Chemical Family: Polyurethanes (PU)

Features: Dimensional Stability, Excellent Initial Seal Strength, Fast Setting, Good Adhesion, Good Thermal Stability, High Temperature Strength, Hot Tack Strength, Low Outgassing, Low Temperature Flexibility, No Expulsion During Application, No Flow During Application, Quick Strengthening

Technical Data Sheet
View All Documents

Enhanced TDS

Identification

Chemical Family
GBU
RTU Product Type

Categories

Application Information

Cure Method

Applications

Application Area
Compatible Substrates & Surfaces

Applications & Uses

Application Instructions
  • H.B. Fuller EV Bond 720 is designed to be used with heated platen-style melting machine that transfers material from pails or drums to a nozzle enough to form a bead and dispense into the housing.
  • Substrate surface must be clean, dry, and free from oils and dust.
  • Non-polar substrates must be surface treated (e.g. plasma treated) prior to adhesive application.
  • If the equipment is to be shut down for extended periods of time, we suggest purging the system with H.B. Fuller Swift®Clean 9037.

Features

Ready-to-Use Product Features

Features & Benefits

Key Attributes
  • Fast initial set strength, building 50% of its maximum cured strength within the 3-5 minutes after bond allowing short wait for pressure testing.
  • Rapid Dimensional Stability
  • Good low temperature flexibility
  • One component requires no mixing
  • Low outgassing
  • Excellent manufacturing thermal stability

Packaging & Availability

Country Availability
Packaging Type
Regional Availability
  • Europe
  • North America
Typical Packaging
  • 286mm diameter pails (USA size)
  • 280mm diameter pails (Europe size)
  • 55 gallons / 200-liter drums

Note: Packaging may contain liners.

Physical Properties

Color (Properties)
Physical Form

Properties

Application Temperature:
160.0~180.0 °C
Density:
1160.0 kg/m³
Shelf Life:
12.0 months
Specific Gravity:
1.16
Tensile Strength:
18.0 MPa
Viscosity:
13000.0~18000.0 cps
Processing Properties
Value Units Test Method / Conditions
Application Temperature 160 - 180 °C -
Clamping/Fixture Time 3 - 4 minutes HBF Internal
Density 1.16 g/cm³ HBF Internal: TMHM-017
Open Time (adhesive bead) 90 seconds ASTM D3163
Over-Lap Shear Initial Strength (at 3 min, nickel, polycarbonate to polycarbonate) 1.3 MPa ASTM D3163
Viscosity (at 163°C, spindle 27, 10rpm) 13,000 - 18,000 mPa.s ASTM D1084
Cured Properties
Value Units Test Method / Conditions
Elongation at Break (type V) 150 - 200 % ASTM D638
Hardness 90 - 95 Shore A ASTM D2240
Lap Shear Strength (at -30°C, polycarbonate to polycarbonate) 1.85 MPa ASTM D3163
Lap Shear Strength (at 120°C, polycarbonate to polycarbonate) 1.89 MPa ASTM D3163
Lap Shear Strength (at 23°C, polycarbonate to polycarbonate) 7 MPa ASTM D3163
Ultimate Tensile Strength (type V) 18 MPa ASTM D638
Young's Modulus (type V) 200 - 250 MPa ASTM D638
Typical Properties
Value Units Test Method / Conditions
Storage Temperature 10 - 35 °C -

Storage & Handling

Storage Conditions
  • Product should be stored in a clean and dry condition in an original and unopened container between 10°C and 35°C.
  • Shelf Life: 12 months from date of manufacture, in original unopened container at 23°C.
Shelf Life
12 months

Technical Details & Test Data

Curing Profile

Under standard conditions (23°C, 50% RH), full cure will take approximately 14 days. Any deviation from standard conditions will change the cure rate. Additionally, cure rates and completeness of cure will vary with adhesive thickness and the substrate's moisture permeability.